Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
BMC Oral Health ; 24(1): 415, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38575886

RESUMO

BACKGROUND: The objective of the present study was to evaluate the reliability of an augmented reality drilling approach and a freehand drilling technique for the autotransplantation of single-rooted teeth. MATERIALS AND METHODS: Forty samples were assigned to the following surgical techniques for drilling guidance of the artificial sockets: A. augmented reality technique (AR) (n = 20) and B. conventional free-hand technique (FT) (n = 20). Then, two models with 10 teeth each were submitted to a preoperative cone-beam computed tomography (CBCT) scan and a digital impression by a 3D intraoral scan. Afterwards, the autotrasplanted teeth were planned in a 3D dental implant planning software and transferred to the augmented reality device. Then, a postoperative CBCT scan was performed. Data sets from postoperative CBCT scans were aligned to the planning in the 3D implant planning software to analize the coronal, apical and angular deviations. Student's t-test and Mann-Whitney non-parametric statistical analysis were used to analyze the results. RESULTS: No statistically significant differences were shown at coronal (p = 0.123) and angular (p = 0.340) level; however, apical deviations between AR and FT study groups (p = 0.008) were statistically significant different. CONCLUSION: The augmented reality appliance provides higher accuracy in the positioning of single-root autotransplanted teeth compared to the conventional free-hand technique.


Assuntos
Realidade Aumentada , Implantes Dentários , Cirurgia Assistida por Computador , Humanos , Transplante Autólogo , Reprodutibilidade dos Testes , Desenho Assistido por Computador , Tomografia Computadorizada de Feixe Cônico/métodos , Imageamento Tridimensional
2.
Aust Endod J ; 49 Suppl 1: 481-487, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37154212

RESUMO

Dens Invaginatus (DI) or dens in dente is an uncommon anomaly which mostly affects permanent lateral incisors, and it is very rare in molars. This article presents the conservative endodontic management of four different cases of DI and a discussion of the endodontic literature for this malformation. Three upper lateral incisors Type II, IIIa and IIIb, and an upper first molar Type II are shown. The most conservative approach possible was carried out. Three of the cases were obturated using the continuous wave technique. In one of the cases, it was possible to treat only the invagination with MTA and preserve the pulp vitality of the main canal. To make a correct diagnosis and to treat in the most conservative way possible, a DI is necessary to know its classification and use tools such as CBCT and magnification.


Assuntos
Dens in Dente , Materiais Restauradores do Canal Radicular , Humanos , Tratamento do Canal Radicular/métodos , Materiais Restauradores do Canal Radicular/uso terapêutico , Dens in Dente/diagnóstico por imagem , Dens in Dente/terapia , Tratamento Conservador , Seguimentos
3.
J Clin Med ; 12(7)2023 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-37048739

RESUMO

Regenerative endodontic treatment (RET) has been considered a reliable procedure to treat immature necrotic teeth; however, the effect of dental trauma on the prognosis of RET is questionable. This systematic review aimed to evaluate the current level of evidence for revascularization techniques (the RET) in the management of traumatized necrotic immature permanent teeth with or without periapical radiolucent areas. Four electronic databases-PubMed, Web of Science, Scopus, and Embase-were searched until November 2022. Only randomized clinical trials, cohort studies, and case-control studies with a minimum of 10 cases and 12 months of follow-ups were included. The search identified 363 preliminary results. After discarding the duplicates and screening the titles, abstracts, and full texts, 13 articles were considered eligible. The results showed that RET techniques seemed to have high survival and success rates, 93.8% and 88.3%, respectively, in the treatment of traumatized necrotic immature permanent teeth. Root maturation with RET techniques seemed to be lower in traumatized teeth. Future studies are needed to evaluate root maturation in traumatized teeth using 3-dimensional radiographic evaluations. In addition, the lack of literature on the studies comparing RET and apexification (calcium hydroxide or an MTA) in the treatment of traumatized necrotic immature teeth highlights the necessity for high-level clinical studies comparing these treatment modalities.

4.
Artigo em Inglês | MEDLINE | ID: mdl-36141439

RESUMO

INTRODUCTION: The purpose of this study was to compare and contrast the accuracy of endodontic access cavities created using an augmented reality appliance to those performed using the conventional technique. MATERIALS AND METHODS: 60 single-rooted anterior teeth were chosen for study and randomly divided between two study groups: Group A-endodontic access cavities created using an augmented reality appliance as a guide (n = 30) (AR); and Group B-endodontic access cavities performed with the manual (freehand) technique (n = 30) (MN). A 3D implant planning software was used to plan the endodontic access cavities for the AR group, with a cone-beam computed tomography (CBCT) and 3D intraoral surface scan taken preoperatively and subsequently transferred to the augmented reality device. A second CBCT scan was taken after performing the endodontic access cavities to compare the planned and performed endodontic access for accuracy. Therapeutic planning software and Student's t-test were used to analyze the cavities at the apical, coronal, and angular levels. The repeatability and reproducibility of the digital measurement technique were analyzed using Gage R&R statistical analysis. RESULTS: The paired t-test found statistically significant differences between the study groups at the coronal (p = 0.0029) and apical (p = 0.0063) levels; no statistically significant differences were found between the AR and MN groups at the angular (p = 0.6596) level. CONCLUSIONS: Augmented reality devices enable the safer and more accurate performance of endodontic access cavities when compared with the conventional freehand technique.


Assuntos
Realidade Aumentada , Tomografia Computadorizada de Feixe Cônico , Humanos , Reprodutibilidade dos Testes , Software
5.
J Clin Med ; 11(11)2022 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-35683530

RESUMO

The present study aims to evaluate and contrast the function of the rotational speed of NiTi alloy endodontic rotary files on how resistant they are to dynamic cyclic fatigue. Methods: A total of 150 NiTi alloy endodontic rotary files with similar geometrical design and metallurgical properties were randomly divided into study groups: Group A: 200 rpm (n = 30); Group B: 350 rpm (n = 30); Group C: 500 rpm (n = 30); Group D: reciprocating movement at 350 rpm with 120° counterclockwise and 30° clockwise motion (350 rpm+) (n = 30); and Group E: reciprocating movement at 400 rpm with 120° counterclockwise and 30° clockwise motion (400 rpm+) (n = 30). A dynamic device was designed to carry out dynamic cyclic fatigue tests using artificial root canal systems made from stainless steel with an apical diameter of 250 µm, 5 mm radius of curvature, 60° curvature angle, and 6% taper, and 20 mm in length. A Weibull statistical analysis and ANOVA test were used to analyze the results. Results: The ANOVA analysis showed differences in time to failure among all the study groups that were of statistical significance (p < 0.001). Conclusions: NiTi alloy endodontic rotary files using reciprocating movement at 350 rpm with 120° counterclockwise and 30° clockwise motion exhibit greater resistance to dynamic cyclic fatigue than files used with a reciprocating movement at 400 rpm with 120° counterclockwise and 30° clockwise motion, continuous rotational speed at 200 rpm, continuous rotational speed at 350 rpm, or continuous rotational speed at 500 rpm; it is therefore advisable to use reciprocating movements at a low speed.

6.
J Clin Med ; 11(9)2022 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-35566767

RESUMO

In this article, the effects of cross-section and pitch on the mechanical response of NiTi endodontic files is studied by means of finite element analyses. The study was conducted over a set of eight endodontic rotary files, whose geometry was obtained from combinations of two cross-sections (square and triangular) and four pitches. Each file was subjected to bending and torsional analyses, simulating the testing conditions indicated in the ISO 3630 Standard, in order to assess their stiffness and mechanical strength. The results indicate that endodontic files with a square cross-section have double the stiffness of those with triangular cross-sections, both in terms of bending and torsion. For both loading modes, endodontic files with a triangular cross-section can undergo larger deformations before overload failure than those with a square cross-section: up to 20% more in bending and 40% in torsion. Moreover, under equivalent boundary conditions, endodontic files with triangular cross-sections present a higher fatigue life than those with square cross-sections: up to more than 300% higher for small pitches. The effect of pitch on the stiffness and strength of the file is smaller than that of the cross-section shape, but smaller pitches could be beneficial when using a triangular cross-section, as they increase the bending flexibility, fatigue life, and torsion stiffness. These results suggest a clinical recommendation for the use of files with a triangular-shaped cross-section and a small pitch in order to minimize ledging and maximize fatigue life. Finally, in this study, we reveal the sensitivity of the orientation of files with respect to the bending direction, which must be taken into account when designing, reporting, and interpreting test results under such loading conditions.

7.
Artigo em Inglês | MEDLINE | ID: mdl-35410096

RESUMO

In this study, we compare and analyze the scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX), morphometry and cyclic fatigue resistance of Endogal, PathMax, and Smarttrack novel brands of nickel−titanium (NiTi) alloy endodontic files. Material and Methods: Thirty sterile NiTi endodontic rotary files were randomly selected and assigned to one of the following study groups: A: 25.08 F2 Endogal (EDG) (n = 10); B: 25.08 F2 Path Max Pro (PMP) (n = 10); and C: 25.06 Smarttrack (ST) (n = 10). Dynamic cyclic fatigue tests were conducted using a cyclic fatigue device in stainless steel artificial root canal systems with an apical diameter of 250 µm, curvature angle of 60°, radius of curvature of 3 mm, and taper of 6%. Additionally, we analyzed the NiTi endodontic rotary files using EDX, SEM, and morphometry after micro-CT scanning. The results were analyzed using Weibull statistical analysis and ANOVA testing. Results: SEM, EDX, and morphometric analyses showed differences between the three novel brands of NiTi endodontic rotary files. Moreover, statistically significant differences were observed between the number of cycles to failure and time to failure of the three novel brands of NiTi endodontic rotary files (p < 0.001). Conclusions: Smarttrack NiTi alloy endodontic reciprocating files display greater resistance to cyclic fatigue than Endogal and Path Max Pro NiTi alloy endodontic rotary files, due to the reciprocating movement and metallurgical composition.


Assuntos
Níquel , Titânio , Ligas , Desenho de Equipamento , Falha de Equipamento , Microscopia Eletrônica de Varredura , Níquel/química , Preparo de Canal Radicular , Titânio/química
8.
Artigo em Inglês | MEDLINE | ID: mdl-35328891

RESUMO

The present study seeks to describe a novel digital measurement technique for analyzing the wear volume of controlled memory (CM)-wire NiTi alloy endodontic reciprocating files after clinical use. MATERIAL AND METHODS: Ten CM-wire NiTi endodontic reciprocating files were randomly used in ten first upper molar teeth within four root canals. The CM-wire NiTi alloy endodontic reciprocating files were subjected to preoperative and postoperative micro-computed tomography (micro-CT) scans to obtain accurate digital imaging and communication on medicine (DICOM) digital files, which were segmented using intensity-based thresholding and an exclusive OR (XOR) logical operation (Boolean algebra logical operator) to obtain a mask of the location to localize and quantify the wear volume of the CM-wire NiTi alloy endodontic reciprocating files. Gage repeatability and reproducibility statistical analysis was applied to assess the reproducibility and repeatability of this measurement technique. RESULTS: The analysis showed a repeatability and reproducibility of 0.00% for the digital measurement technique used to analyze the wear volume of CM-wire NiTi alloy endodontic reciprocating files after clinical use. Wear was mostly identified at the tip and cutting edges of the CM-wire NiTi alloy endodontic reciprocating files. CONCLUSIONS: This novel digital measurement technique is a repeatable, reproducible, and accurate method of quantifying the wear volume of CM-wire NiTi alloy endodontic reciprocating files after clinical use.


Assuntos
Ligas , Preparo de Canal Radicular , Desenho de Equipamento , Reprodutibilidade dos Testes , Titânio , Microtomografia por Raio-X
9.
Clin Oral Investig ; 26(6): 4391-4405, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35149904

RESUMO

OBJECTIVES: This study aimed at evaluating the microtensile bond strength (µTBS) and the resin-dentine ultramorphology (24 h and 10 months ageing) of contemporary universal adhesives applied in self-etch (SE) or etch-and-rinse (ER) mode. MATERIALS AND METHODS: Sixty-four sound human molars were collected and randomly allocated in 4 main experimental groups (n = 16) according to the adhesive system employed and subsequently divided into two subgroups depending on their application mode SE or ER (n = 8): ZipBond X (ZBX-SE; ZBX-ER), Prime and Bond Active (PBA-SE; PBA-ER), Clearfil Universal Bond Quick (CBQ-SE; CBQ-ER) or Scotchbond Universal (SCH-SE; SCH-ER). The specimens were cut into sticks with a cross-sectional area of approximately 0.9 mm2 and subjected to µTBS testing at 24 h or after 10 months of ageing in artificial saliva (AS). Five representative fractured specimens from each group were analysed using field-emission scanning electron microscopy (FE-SEM). Resin-dentine slabs (Ø 0.9mm2) from each experimental group were immersed in Rhodamine B and subsequently analysed using confocal microscopy analysis (CLSM). The µTBS results were analysed using a two-way ANOVA and Newman-Keuls multiple-comparison test (α = 0.05). RESULTS: ZBX, PBA and SCH exhibited greater µTBS values than CQB at 24 h in both SE and ER modes (p < 0.05). CQB showed a significant decrease in µTBS values after ageing both when used in SE and ER mode (p < 0.05). ZBX-ER exhibited no significant differences in the µTBS test after ageing (p > 0.05), while a significant drop in µTBS was seen in SCH-ER and APB-ER after 10-month ageing (p < 0.05). Clear signs of degradation were evident in the resin-dentine interface created with CQB regardless of the application mode or the ageing time. In APB-ER and SCH-ER groups, such signs of degradation were evident after ageing in AS. ZBX showed slight dye infiltration both when used in ER and SE mode. CONCLUSIONS: The long-term bonding performance of modern universal adhesives is usually influenced by the adhesive strategy employed; self-etching application should be prioritised during dentine bonding. Moreover, the use of shortened bonding protocols may compromise the quality of the resin-dentine interface and the bonding performance of most modern universal adhesives. CLINICAL RELEVANCE: The use of etch-and-rinse bonding procedures, as well as "shortened" application protocols should be eluded when using modern universal adhesives in dentine. However, new generation universal adhesives based on innovative chemical formulations may probably allow clinicians to achieve long-term bonding performance with such simplified system also when employed in ER mode.


Assuntos
Colagem Dentária , Adesivos Dentinários , Condicionamento Ácido do Dente/métodos , Adesivos/análise , Resinas Compostas/química , Colagem Dentária/métodos , Cimentos Dentários/química , Dentina/química , Adesivos Dentinários/química , Humanos , Teste de Materiais , Metacrilatos/química , Cimentos de Resina/química , Propriedades de Superfície , Resistência à Tração
10.
J Clin Med ; 11(2)2022 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-35054032

RESUMO

The objective of the present study was to evaluate and compare the dentin removal capacity of Endogal Kids and Reciproc Blue NiTi alloy endodontic reciprocating systems for root canal treatments in primary second molar teeth via a micro-computed tomography (micro-CT) scan. MATERIALS AND METHODS: Sixty root canal systems in fifteen primary second molar teeth were chosen and classified into one of the following study groups: A: EK3 Endogal Kids (n = 30) (EDG) and B. R25 Reciproc Blue (n = 30) (RB). Preoperative and postoperative micro-CT scans were uploaded into image processing software to analyze the changes in the volume of root canal dentin using a mathematical algorithm that enabled progressive differentiation between neighboring pixels after defining and segmenting the root canal systems in both micro-CT scans. Volumetric variations in the root canal system and the root canal third were calculated using a t-test for independent samples or a nonparametric Mann-Whitney-Wilcoxon test. RESULTS: Statistically significant differences (p = 0.0066) in dentin removal capacity were found between the EDG (2.89 ± 1.26 mm3) and RB (1.22 ± 0.58 mm3) study groups for the coronal root canal third; however, no statistically significant differences were found for the middle (p = 0.4864) and apical (p = 0.6276) root canal thirds. CONCLUSIONS: Endogal and Reciproc Blue NiTi endodontic reciprocating systems showed similar capacity for the removal of root canal dentin, except for the coronal root canal third, in which the Reciproc Blue NiTi endodontic reciprocating system preserved more root canal dentin tissue.

11.
Artigo em Inglês | MEDLINE | ID: mdl-35055540

RESUMO

This study aimed at analyzing and comparing the ease of removal of fractured nickel-titanium (NiTi) endodontic rotary files from the root canal system between the ultrasonic tips and the Endo Rescue appliance removal systems, as well as comparing the volume of dentin removed between ultrasonic tips and the Endo Rescue appliance using a micro-computed tomography (micro-CT) scan. MATERIAL AND METHODS: Forty NiTi endodontic rotary files were intentionally fractured in 40 root canal systems of 20 lower first molar teeth and distributed into the following study groups: A: Ultrasonic tips (n = 20) (US) and B: Endo Rescue device (n = 20) (ER). Preoperative and postoperative micro-CT scans were uploaded into image processing software to analyze the volumetric variations of dentin using an algorithm that enables progressive differentiation between neighboring pixels after defining and segmenting the fractured NiTi endodontic rotary files and the root canal systems in both micro-CT scans. A non-parametric Mann-Whitney-Wilcoxon test or t-test for independent samples was used to analyze the results. RESULTS: The US and ES study groups saw 8 (1 mesiobuccal and 7 distal root canal system) and 3 (distal root canal system) fractured NiTi endodontic rotary files removed, respectively. No statistically significant differences were found in the amount of dentin removed between the US and ER study groups at the mesiobuccal (p = 0.9109) and distal root canal system (p = 0.8669). CONCLUSIONS: Ultrasonic tips enable greater ease of removal of NiTi endodontic rotary files from the root canal system, with similar amounts of dentin removal between the two methods.


Assuntos
Níquel , Preparo de Canal Radicular , Cavidade Pulpar/diagnóstico por imagem , Desenho de Equipamento , Preparo de Canal Radicular/métodos , Titânio , Microtomografia por Raio-X
12.
J Clin Med ; 10(23)2021 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-34884394

RESUMO

This article describes a numerical procedure for estimating the fatigue life of NiTi endodontic rotary files. An enhanced finite element model reproducing the interaction of the endodontic file rotating inside the root canal was developed, which includes important phenomena that allowed increasing the degree of realism of the simulation. A method based on the critical plane approach was proposed for extracting significant strain results from finite element analysis, which were used in combination with the Coffin-Manson relation to predict the fatigue life of the NiTi rotary files. The proposed procedure is illustrated with several numerical examples in which different combinations of endodontic rotary files and root canal geometries were investigated. By using these analyses, the effect of the radius of curvature and the angle of curvature of the root canal on the fatigue life of the rotary files was analysed. The results confirm the significant influence of the root canal geometry on the fatigue life of the NiTi rotary files and reveal the higher importance of the radius of curvature with respect to the angle of curvature of the root canal.

13.
J Clin Med ; 10(20)2021 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-34682836

RESUMO

The aim of this study was to analyze and compare the influence of the geometrical cross-section design on the dynamic cyclic fatigue resistance of NiTi endodontic rotary files. MATERIALS AND METHODS: Forty sterile endodontic rotary files were selected and distributed into the following study groups: A: 25.06 double S-shaped cross-section NiTi alloy endodontic rotary files (Mtwo) (n = 10); B: 20.04 rectangular cross-section NiTi alloy endodontic rotary files (T Pro E1) (n = 10); C: 25.04 convex triangular cross-section NiTi alloy endodontic rotary files (T Pro E2) (n = 10); and D: 25.06 triangular cross-section NiTi alloy endodontic rotary files (T Pro E4) (n = 10). A cyclic fatigue device was used to conduct the static cyclic fatigue tests with stainless steel artificial root canal systems with 200 µm and 250 µm apical diameter, 60° curvature angle, 3 mm radius of curvature, 20 mm length, and 4% and 8% taper. The results were analyzed using the ANOVA test and Weibull statistical analysis. RESULTS: All the pairwise comparisons presented statistically significant differences between the time to failure and number of cycles to failure for the cross-section design study groups (p < 0.001). CONCLUSIONS: the double S-shaped cross-section of Mtwo NiTi endodontic files shows higher cyclic fatigue resistance than the rectangular cross-section of T Pro E1 NiTi endodontic files, the convex triangular cross-section of T Pro E2 NiTi endodontic files, and the triangular cross-section of T Pro E4 NiTi endodontic files.

14.
J Pers Med ; 11(9)2021 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-34575709

RESUMO

The aim of this study was to analyze the accuracy and predictability of the indirect bonding technique of fixed buccal multibracket appliances using a customized iterative closest point algorithm. MATERIALS AND METHODS: A total of 340 fixed buccal multibracket appliances were virtually planned and bonded on 34 experimental anatomically based acrylic resin models by using orthodontic templates designed and manufactured to indirectly bond the fixed buccal multibracket appliances. Afterwards, the models were submitted to a three-dimensional impression technique by an intraoral scanner, and the standard tessellation language digital files from the virtual planning and the digital impression were aligned, segmented, and realigned using morphometric software. Linear positioning deviations (mm) of the fixed buccal multibracket appliances were quantified at mesio-distal, bucco-lingual/palatal, and gingival/occlusal (vertical) planes, and angular deviations (°) were also recorded by analyzing the torque, tip, and rotation using a customized iterative closest point algorithm, the script for which allowed for an accuracy measurement procedure by comparing the tessellation network positioning of both standard tessellation language digital files. RESULTS: The mean mesio-distal deviation was -0.065 ± 0.081 mm, the mean bucco-lingual/palatal deviation was 0.129 ± 0.06 m, the mean vertical deviation was -0.094 ± 0.147 mm, the mean torque deviation was -0.826 ± 1.721°, the mean tip deviation was -0.271 ± 0.920°, and the mean rotation deviation was -0.707 ± 0.648°. CONCLUSION: The indirect bonding technique provides accurate and predictable positioning of fixed buccal multibracket appliances.

15.
J Clin Exp Dent ; 13(5): e473-e478, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33981394

RESUMO

BACKGROUND: Intraoral scanners have been developing during last years. The aim of this study was to know if digital impressions achieve a marginal adaptation in overlays as well as conventional impressions with silicone. MATERIAL AND METHODS: Sixty-two extracted molars were selected. The samples were prepared for MOD overlays. The teeth were divided into two groups (n=31). Group 1: impressions were made with silicone (Express™ Impression, 3M ESPE) and overlays were manufactured with Sinfony composite (3M ESPE) by the laboratory technician. Group 2: impressions were taken with the scanner True Definition (TD, 3M ESPE) and under Lava Ultimate CAD/CAM Restorative composite (3M ESPE) were produced the restorations. Under 32x magnification images of vestibular, lingual, mesial and distal were capture in all the samples. Then the fit of the restorations was evaluated before and after cementation. Data were analysed statistically applying ANOVA and Bonferroni test. RESULTS: The marginal gap was better in TD group before (169,76 ± 54,15 µm) and after (145,16 ± 57,89 µm) cementation than in the silicone group (190,89 ± 58,18 µm) (187,47 ± 81,29 µm). The lowest marginal gap was in oclusal surface and the higher value was in the proximal margin for all the groups. CONCLUSIONS: Digital impressions regarding marginal adaptation achieve better results than conventional impressions. Key words:Composite onlays, overlays, restorative, CAD/CAM, intraoral scanner, silicone impressions, marginal adaptation.

16.
J Clin Med ; 10(6)2021 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-33803810

RESUMO

The present study aims to evaluate the effectiveness of an XP-endo non-surgical root canal re-treatment system in removing both GuttaCore and Thermafil gutta-percha carrier-based root canal filling materials from straight root canal systems using micro-computed tomography (micro-CT) analysis. The study was performed on 20 single-rooted upper teeth, which were randomly allocated into the following study groups: Group A, Thermafil and AH Plus sealer (n = 10); Group B, GuttaCore and AH Plus sealer (n = 10). Before and after the non-surgical root canal re-treatment procedure, the samples were submitted for a micro-CT analysis. The volume of the root canal filling material (mm3), the volume of the remaining root canal filling material (mm3) and the time (minutes) needed to remove the root canal filling material were also recorded. Student's t-test was used to analyze the results. No statistically significant differences were found between the volume of the remaining root canal filling material in the GuttaCore and Thermafil root canal filling systems at the coronal third (p = 0.782), middle third (p = 0.838) or apical third (p = 0.882) of the straight root canal systems; however, the GuttaCore required a statistically significant (p = 0.037) shorter amount of time (4.72 ± 0.76 min) to be removed than the Thermafil carrier-based root canal filling material (5.92 ± 1.42 min). The XP-endo Finisher non-surgical endodontic re-treatment system removes both GuttaCore and Thermafil gutta-percha carrier-based root canal filling materials from straight root canal systems, although removal of the GuttaCore gutta-percha carrier-based root canal filling material required less time.

17.
J Clin Med ; 9(11)2020 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-33233442

RESUMO

BACKGROUND: The aim of this study was to analyze the influence of NiTi alloy in endodontic rotary instruments on cyclic fatigue resistance. METHODS: One hundred and sixty-four (164) sterile endodontic rotary files were selected and distributed into the following study groups: A: 25.08 F2 ProTaper Universal (PTU) (n = 41); B: 25.06 X2 ProTaper Next (PTN) (n = 41); C: 25.08 F2 ProTaper Gold (PTG) (n = 41), and D: 25.06 ProFile Vortex Blue (PVB) (n = 41). A cyclic fatigue device was designed to conduct the static cyclic fatigue tests with stainless steel artificial root canals systems with 250 µm apical diameter, 60° curvature angle, 5 mm radius of curvature, 20 mm length, and 6% (25.06) and 8% taper (25.08). Failure of the endodontic rotary instrument was detected by a single operator through direct observation and was also filmed to allow measurement of the exact time to failure. Results were analyzed using the ANOVA test and Weibull statistical analysis. RESULTS: All pairwise comparisons presented statistically significant differences between the time to failure for the NiTi alloy study groups (p < 0.001), except between the PTN and PVB study groups (p = 0.379). In addition, statistically significant differences between the number of cycles to failure for the NiTi alloy study groups (p < 0.001) were also observed. CONCLUSIONS: The NiTi CM-Gold wire alloy of the ProTaper Gold endodontic rotary files resulted in greater resistance to cyclic fatigue than ProFile Vortex Blue, ProTaper Next, and ProTaper Universal endodontic rotary files.

18.
Br Dent J ; 229(7): 450-458, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-33037365

RESUMO

Minimally invasive (MI) concepts in restorative dentistry in the year 2020 request from the practitioner not only a scientifically supported rationale for carious tissue removal/excavation and defect-oriented, biological cavity preparation, but also a deep understanding of how to ensure a biomechanically stable and durable restoration in different clinical situations by applying different restorative options. Bio-interactive materials play an increasingly relevant role, as they not only replace diseased or lost tissue, but also optimise tissue mineral recovery (among other properties) when used in restorative and preventive dentistry. Indeed, this is of certain interest in MI restorative dentistry, especially in those cases where gap formation jeopardises the integrity of the margins along resin composite restorations, causing penetration of bacteria and eventually promoting the formation of secondary caries. Recently, the interest in whether ion-releasing materials may reduce such biofilm penetration into margin gaps and reduce such a risk for development and propagation of secondary caries is growing significantly among clinicians and scientists. The aim of this article was to explore mechanisms involved in the process that allow mineral deposition at the interface between such materials and dentine, and to describe how conventional 'bioactive' restorative materials currently available on the market may benefit treatments in MI dentistry.


Assuntos
Cárie Dentária , Preparo da Cavidade Dentária , Resinas Compostas , Assistência Odontológica , Cárie Dentária/terapia , Materiais Dentários , Restauração Dentária Permanente , Humanos
19.
Med. oral patol. oral cir. bucal (Internet) ; 25(5): e592-e598, sept. 2020. tab, graf, ilus
Artigo em Inglês | IBECS | ID: ibc-196514

RESUMO

BACKGROUND: While traumatic dental injuries (TDI) are an increasingly frequent occurrence in everyday dental practice, little research on TDIs has been published in Spain. The aim of this study was to determine the incidence of TDIs in a population in Valencia (Spain) and investigate influential variables. In addition, a protocol for TDI data collection is proposed. MATERIAL AND METHODS: This retrospective study compiled data from patients attending a private dental clinic between January 2003 and December 2014. The data were collected using a specially-elaborated protocol entitled "Emergency care of acute dental trauma". Patients responded to each item, and data was added from case radiographs and photographs. Data were entered in a Microsoft Office Excel spreadsheet and submitted for analysis by SPSS 15.0 software (Chicago, IL) applying 2-way analysis of variance (ANOVA) (p < 0.01). RESULTS: 481 TDIs in 251 patients were examined at a private dental practice in Valencia. The population comprised 62.5% men and 37.5% women, aged 1 to 78 years. The highest frequency of tooth injuries occurred in children aged 9 years or younger. The most frequent injury was non-complicated crown fracture (43.2%). Upper central incisors were the most commonly affected teeth. The most frequent place where TDI was produced was in the street (28.7%), tripping over an immobile object being the most common cause (29%). CONCLUSIONS: Thanks to the protocol elaborated for the purposes of this work, it was possible to compile a large quantity of data on TDI, facilitating future prevention and comparison with other regions. The results obtained concur with those published in the literature


No disponible


Assuntos
Humanos , Masculino , Feminino , Lactente , Pré-Escolar , Criança , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Traumatismos Dentários/epidemiologia , Estudos Transversais , Estudos Retrospectivos , Traumatismos Dentários/etiologia , Incidência , Análise de Variância , Fatores de Tempo , Má Oclusão/etiologia , Espanha/epidemiologia
20.
J Clin Med ; 9(6)2020 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-32630387

RESUMO

The aim of this study is to analyze and compare the efficacy of three non-surgical endodontic retreatment techniques in removing a carrier-based root canal filling material from straight root canal systems. The study was performed on 99 single-rooted extracted teeth using the ProTaper Gold endodontic rotary system up to the F2 file (Dentsply Maillefer, Baillagues, Switzerland), which were sealed with GuttaCore (Dentsply Maillefer, Ballaigues, Switzerland) and AH plus epoxy resin sealer (Dentsply DeTrey, Konstanz, Germany) and randomly assigned to the following non-surgical retreatment techniques: ProTaper Retreatment endodontic rotary instruments (D1-D3 files, Dentsply Maillefer, Ballaigues, Switzerland; n = 33, PTR), Reciproc Blue endodontic reciprocating instrument (R50, VDW, Munich, Germany; n = 33, RCB50), and a combined root canal retreatment technique between Gates-Glidden drills (sizes #3 and #2, Dentsply Maillefer, Ballaigues, Switzerland) and Hedstrom files (file size 35, 30, and 25, Dentsply Maillefer, Ballaigues, Switzerland; n = 33; H-GG). All of the teeth were submitted twice to a micro-computed tomography (micro-CT) scan, before and after non-surgical endodontic retreatment procedures. The volume of root canal filling material (mm3), volume of remaining root canal filling material (mm3), non-surgical endodontic retreatment working time (min), proportion of remaining root canal filling material (%), and efficacy of root canal filling material removal between the non-surgical endodontic retreatment techniques were analyzed using ANOVA one-way statistical analysis. Statistically significant differences were observed between the proportions of remaining root canal filling material of PTR and H-GG (p = 0.018), between the non-surgical endodontic retreatment working times (min; p < 0.001), and between the efficacies of root canal filling material removal by the non-surgical endodontic retreatment techniques (p = 0.009). However, the non-surgical endodontic retreatment systems allow for similar carrier-based root canal filling material removal.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...